Characterization of Preliminary Breakdown Pulse Trains in Negative Cloud-To-Ground Flashes Recorded during A Rainy Season in The Bogota Savannah, Colombia

dc.creatorGranados, Camilo A.
dc.creatorRojas , Herbert E.
dc.creatorRomán, Francisco J.
dc.date2022-11-21
dc.date.accessioned2025-10-01T23:52:47Z
dc.descriptionLightning-generated electric field measurement is used to characterize cloud-to-ground (CG) flashes. Prior to the first return stroke (FRS), these signals sometimes exhibit a pulse train, known as preliminary breakdown pulses (PBP), whose study provides information about the first event that originate the breakdown process inside the cloud. Considering that characteristics of PBPs may change according to geographical conditions, in this work, six parameters (temporal and magnitude) associated with 69 trains identified in negative CG flashes that occurred in the Bogota savannah, Colombia were analyzed. The signatures were recorded in 2017 using a fast response antenna (10 MHz bandwidth), a 100 ns sampling time and a window of 500 ms. Among the most relevant results, it was found that the train duration ( ) varied from 0.5 ms up to 5.2 ms with arithmetic mean (AM) of 1.74 ms, while the time interval between the peak of the train and the FRS (PBP-FRS) had an AM and a geometric mean (GM) of 35.7 ms and 10.2 ms, respectively. On the other hand, the ratio between the peak value of the PBP and its FRS ( ) exhibited an AM of 0.7 and a GM of 0.56. It was concluded that PBP train starts with low amplitude pulses, later increases its magnitude in the central region and decreases at the end. Furthermore, bipolar pulses with similar polarity to that of the FRS were identified at the beginning and in the middle of the train, while unipolar pulses were observed at the end of the signatures.en-US
dc.descriptionLa medición del campo eléctrico generado por rayos es comúnmente usada para caracterizar rayos nube-tierra (CG). Previo a la primera descarga de retorno (FRS), estas señales exhiben algunas veces un tren de pulsos conocido como pulsos de descargas preliminares (PBP), cuyo estudio proporciona información sobre el primer evento que origina el proceso de descarga dentro de la nube. Considerando que las características de los PBP pueden cambiar de acuerdo con las condiciones geográficas, en este trabajo se analizaron seis parámetros (temporales y de magnitud) asociados a 69 trenes identificados en rayos CG negativos ocurridos en la Sabana de Bogotá, Colombia. Las señales se registraron en 2017 usando una antena de respuesta rápida (ancho de banda de 10 MHz), un tiempo de muestreo de 100 ns y una ventana de 500 ms. Dentro de los resultados más relevantes se encontró que la duración del tren ( ) varió entre 0.5 ms y 5.2 ms con una media aritmética (AM) de 1.74 ms, mientras el tiempo entre el pico del tren y el FRS (PBP-FRS) tuvo una AM y una media geométrica (GM) de 35.7 ms y 10.2 ms, respectivamente. Por su parte, la relación entre el pico del PBP y su FRS ( ) exhibió una AM de 0.7 y una GM de 0.56. Se concluye que el tren comienza con pulsos de baja amplitud, aumenta su magnitud en la región central y disminuye al final. Adicionalmente, se identificaron pulsos bipolares con polaridad similar a la FRS al principio y en la mitad del tren, mientras pulsos unipolares fueron observados al final de las señales.es-ES
dc.formatapplication/pdf
dc.formatapplication/zip
dc.formattext/xml
dc.formattext/html
dc.identifierhttps://revistas.itm.edu.co/index.php/tecnologicas/article/view/2343
dc.identifier10.22430/22565337.2343
dc.identifier.urihttps://hdl.handle.net/20.500.12622/7820
dc.languageeng
dc.publisherInstituto Tecnológico Metropolitano (ITM)es-ES
dc.relationhttps://revistas.itm.edu.co/index.php/tecnologicas/article/view/2343/2629
dc.relationhttps://revistas.itm.edu.co/index.php/tecnologicas/article/view/2343/2632
dc.relationhttps://revistas.itm.edu.co/index.php/tecnologicas/article/view/2343/2633
dc.relationhttps://revistas.itm.edu.co/index.php/tecnologicas/article/view/2343/2634
dc.relation/*ref*/B. Salimi, K. Mehranzamir, and Z. Abdul-Malek, “Statistical Analysis of Lightning Electric Field Measured Under Equatorial Region Condition,” Procedia Technology, vol. 11, pp. 525–531, 2013, https://doi.org/10.1016/j.protcy.2013.12.224
dc.relation/*ref*/M. A. Uman, Lightning. New York, USA, 2012. Available: https://books.google.com.co/books?id=YdHhYaGjTbYC. Accessed: Sep. 2022
dc.relation/*ref*/C. Schumann, M. M. F. Saba, R. B. G. da Silva, and W. Schulz, “Electric fields changes produced by positives cloud-to-ground lightning flashes,” J. Atmos. Solar-Terrestrial Phys., vol. 92, pp. 37–42, 2013, https://doi.org/10.1016/j.jastp.2012.09.008
dc.relation/*ref*/V. Rakov, “Characterization of lighting electromagnetic fields and their modeling,” in The International Conference on Electrical Engineering, May 2008, vol. 6, no. 6, pp. 1–31, https://doi.org/10.21608/iceeng.2008.34378
dc.relation/*ref*/V. A. Rakov and M. A. Uman, “Review and evaluation of lightning return stroke models including some aspects of their application,” IEEE Trans. Electromagn. Compat., vol. 40, no. 4 PART 2, pp. 403–426, 1998, https://doi.org/10.1109/15.736202
dc.relation/*ref*/P. Hoole and S. Hoole, Lightning Engineering: Physics, Computer-based Test-bed, Protection of Ground and Airborne Systems, 1st edition. Cham: Springer International Publishing, 2022, https://doi.org/10.1007/978-3-030-94728-6
dc.relation/*ref*/J. Herrera, C. Younes, and L. Porras, “Cloud-to-ground lightning activity in Colombia: A 14-year study using lightning location system data,” Atmos. Res., vol. 203, pp. 164–174, 2018, https://doi.org/10.1016/j.atmosres.2017.12.009
dc.relation/*ref*/H. E. Rojas, A. S. Cruz, and C. A. Cortes, “Characteristics of electric field waveforms produced by negative return strokes in Colombia and their comparison with other regions,” J. Atmos. Solar-Terrestrial Phys., vol. 227, p. 105809, Jan. 2022, https://doi.org/10.1016/j.jastp.2021.105809
dc.relation/*ref*/H. E. Rojas, H. D. Rojas, and C. A. Cortes, “Statistical analysis of negative cloud-to-ground lightning characteristics in Bogota, Colombia based on electric field measurements,” J. Atmos. Solar-Terrestrial Phys., vol. 227, p. 105798, Jan. 2022, https://doi.org/10.1016/j.jastp.2021.105798
dc.relation/*ref*/N. D. Clarence and D. J. Malan, “Preliminary discharge processes in lightning flashes to ground,” Q. J. R. Meteorol. Soc., vol. 83, no. 356, pp. 161–172, Apr. 1957, https://doi.org/10.1002/qj.49708335603
dc.relation/*ref*/N. Azlinda Ahmad et al., “The first electric field pulse of cloud and cloud-to-ground lightning discharges,” J. Atmos. Solar-Terrestrial Phys., vol. 72, no. 2–3, pp. 143–150, Feb. 2010, https://doi.org/10.1016/j.jastp.2009.11.001
dc.relation/*ref*/Z. A. Baharudin, N. A. Ahmad, M. Fernando, V. Cooray, and J. S. Mäkelä, “Comparative study on preliminary breakdown pulse trains observed in Johor, Malaysia and Florida, USA,” Atmos. Res., vol. 117, pp. 111–121, 2012, https://doi.org/10.1016/j.atmosres.2012.01.012
dc.relation/*ref*/J. S. Mäkelä, N. Porjo, A. Mäkelä, T. Tuomi, and V. Cooray, “Properties of preliminary breakdown processes in Scandinavian lightning,” J. Atmos. Solar-Terrestrial Phys., vol. 70, no. 16, pp. 2041–2052, Dec. 2008, https://doi.org/10.1016/j.jastp.2008.08.013
dc.relation/*ref*/C. Gomes, V. Cooray, and C. Jayaratne, “Comparison of preliminary breakdown pulses observed in Sweden and in Sri Lanka,” J. Atmos. Solar-Terrestrial Phys., vol. 60, no. 10, pp. 975–979, Jun. 1998, https://doi.org/10.1016/j.jastp.2013.05.014
dc.relation/*ref*/V. Cooray and R. Jayaratne, “What directs a lightning flash towards ground?,” Sri Lankan J. Phys., vol. 1, p. 1-10, 2000, https://doi.org/10.4038/sljp.v1i0.165
dc.relation/*ref*/F. J. Miranda, O. Pinto Jr., M. M. F. Saba, “Occurrence of characteristic pulses in positive ground lightning in Brazil,” in 19th International Lightning Detection Conference, Apr. 2006, pp. 1–6. [Online]. Available: http://mtc-m16b.sid.inpe.br/col/sid.inpe.br/mtc-m17@80/2006/11.29.16.22/doc/Occurrence%20of%20characteristcs.pdf
dc.relation/*ref*/T. Wu et al., “Preliminary breakdown pulses of cloud-to-ground lightning in winter thunderstorms in Japan,” J Atmos Sol Terr Phys, vol. 102, pp. 91–98, Sep. 2013, https://doi.org/10.1016/j.jastp.2013.05.014
dc.relation/*ref*/Y. Zhang, Y. J. Zhang, W. T. Lu, and D. Zheng, “Analysis and comparison of initial breakdown pulses for positive cloud-to-ground flashes observed in Beijing and Guangzhou,” Atmos. Res., vol. 129–130, pp. 34–41, 2013, https://doi.org/10.1016/j.atmosres.2013.03.006
dc.relation/*ref*/H. E. Rojas, C. A. Rivera, J. Chaves, C. A. Cortés, F. J. Román, and M. Fernando, “New circuit for the measurement of lightning generated electric fields,” in 2017 International Symposium on Lightning Protection (XIV SIPDA), Oct. 2017, pp. 188–194. https://doi.org/10.1109/SIPDA.2017.8116922
dc.relation/*ref*/D. Johari, V. Cooray, M. Rahman, P. Hettiarachchi, and M. Ismail, “Characteristics of Preliminary Breakdown Pulses in Positive Ground Flashes during Summer Thunderstorms in Sweden,” Atmosphere, vol. 7, no. 3, pp. 1–18, Mar. 2016, https://doi.org/10.3390/atmos7030039
dc.relation/*ref*/A. Nag and V. A. Rakov, “Pulse trains that are characteristic of preliminary breakdown in cloud-to-ground lightning but are not followed by return stroke pulses,” J. Geophys. Res. Atmos., vol. 113, no. 1, pp. 1–12, 2008, https://doi.org/10.1029/2007JD008489
dc.relation/*ref*/A. Nag and V. A. Rakov, “Electric Field Pulse Trains Occurring Prior to the First Stroke in Negative Cloud-to-Ground Lightning,” IEEE Trans. Electromagn. Compat., vol. 51, no. 1, pp. 147–150, Feb. 2009, https://doi.org/10.1109/TEMC.2008.2005488
dc.relation/*ref*/V. A. Rakov, M. A. Uman, G. R. Hoffman, M. W. Masters, and M. Brook, “Burst of pulses in lightning electromagnetic radiation: observations and implications for lightning test standards,” IEEE Trans. Electromagn. Compat., vol. 38, no. 2, pp. 156–164, May 1996, https://doi.org/10.1109/15.494618
dc.relation/*ref*/
dc.rightsDerechos de autor 2022 TecnoLógicases-ES
dc.rightshttp://creativecommons.org/licenses/by-nc-sa/4.0es-ES
dc.sourceTecnoLógicas; Vol. 25 No. 55 (2022); e2343en-US
dc.sourceTecnoLógicas; Vol. 25 Núm. 55 (2022); e2343es-ES
dc.source2256-5337
dc.source0123-7799
dc.subjectPulse amplitudeen-US
dc.subjectreturn strokeen-US
dc.subjectelectric field measurementen-US
dc.subjectpreliminary breakdown pulsesen-US
dc.subjectcloud-to-ground lightningen-US
dc.subjectAmplitud del pulsoes-ES
dc.subjectdescarga de retornoes-ES
dc.subjectmedición del campo eléctricoes-ES
dc.subjectpulsos de descargas preliminareses-ES
dc.subjectrayos nube-tierraes-ES
dc.titleCharacterization of Preliminary Breakdown Pulse Trains in Negative Cloud-To-Ground Flashes Recorded during A Rainy Season in The Bogota Savannah, Colombiaen-US
dc.titleCaracterización de trenes de descargas preliminares en rayos nube a tierra negativos registrados durante una temporada de lluvias en la Sabana de Bogotá, Colombiaes-ES
dc.typeinfo:eu-repo/semantics/article
dc.typeinfo:eu-repo/semantics/publishedVersion
dc.typeResearch Papersen-US
dc.typeArtículos de investigaciónes-ES

Archivos

Bloque original

Mostrando 1 - 4 de 4
Cargando...
Miniatura
Nombre:
2343-MUP-VF.pdf
Tamaño:
622.83 KB
Formato:
Adobe Portable Document Format
Cargando...
Miniatura
Nombre:
344272383010_1.epub
Tamaño:
1.15 MB
Formato:
Electronic publishing
Cargando...
Miniatura
Nombre:
344272383010.xml
Tamaño:
74.72 KB
Formato:
Extensible Markup Language
Cargando...
Miniatura
Nombre:
2634.html
Tamaño:
117.12 KB
Formato:
Hypertext Markup Language