dc.description.abstractEl sistema BISS, es un módulo de monitoreo, que está orientado a atender la demanda de servicios médicos en los cuales se debe realizar en un ambiente especializado; un quirófano o en una sala de cirugía. La anestesia se define como un estado de sueño profundo, analgesia o hipnosis, en el cual el paciente no responde a ninguna clase de estímulos. Se han implementado numerosos métodos para llevar a cabo el monitorio de dicho proceso; pero para la profundidad anestésica del paciente se implementó el BISS; es un método que se origina a partir del electroencefalograma, el cual indica la actividad eléctrica del cerebro. La información aportada por el BISS, es traducida en un valor que oscila entre 0 y 100, donde cero es un valor plano que corresponde a coma y 100 cuando el paciente está despierto. Dicho método manifiesta cambios producidos por diferentes factores que alteran la actividad metabólica cerebral, entre ellos la anestesia, temperatura, isquemia, sueño natural y enfermedad neurológica. En síntesis, el método BISS, es un método no invasivo de gran utilidad al momento de inducir al paciente a un estado de hipnosis o sedación para luego proceder a intervenir quirúrgicamente al mismo.spa
dc.format.mimetypeapplication/pdf
dc.language.isospaspa
dc.relation.urihttp://creativecommons. org/licenses/by-nc-nd/4.0/spa
dc.subjectAnalgesia, Anestésia, Biss, Electroencefalograma, Hipnosis, Metabólica, Monitor, Neurológica, Oscilación, Quirófano, Reanimaciónspa
dc.titleImplementación del BISS en sala de cirugía Clínica Cardio Vidspa
dc.publisher.facultyFacultad de Ciencias Exactas y Aplicadasspa
dc.subject.keywordsAnalgesia, Anesthesia, Biss, Electroencephalogram, Hypnosis, Metabolic, Monitor, Neurological, Oscillation, Operating Room, Resuscitationspa
dc.subject.lembAnestesia, sedación, escala de sedaciónspa
dc.description.abstractenglishThe BISS system is a monitoring module, which is oriented to meet the demand for medical services that must be performed in a specialized environment; an operating room or a surgery room. Anesthesia is defined as a state of deep sleep, analgesia or hypnosis, in which the patient does not respond to any kind of stimuli. Numerous methods have been Numerous methods have been implemented to monitor this process, but for depth anesthesia process; but for the anesthetic depth of the patient, the BISS was implemented. BISS was implemented; it is a method that originates from the electroencephalogram, which indicates the electrical activity of the brain. indicates the electrical activity of the brain. The information provided by the BISS is translated into a value that ranges from 0 and 100, where zero is a flat value corresponding to coma and 100 when the patient is awake. This method shows changes produced by different factors that alter brain metabolic activity, including brain metabolic activity, including anesthesia, temperature, ischemia, natural sleep and neurological disease, natural sleep and neurological disease. In summary, the BISS method is a non-invasive method of great usefulness when inducing the patient to when inducing the patient to a state of hypnosis or sedation in order to proceed with surgery proceed to surgical intervention.spa
dc.description.degreenameTecnólogo en Mantenimiento de Equipo Biomédicospa
dc.identifier.instnameinstname:Instituto Tecnológico Metropolitanospa
dc.identifier.reponamereponame:Repositorio Institucional Instituto Tecnológico Metropolitanospa
dc.identifier.repourlrepourl:https://repositorio.itm.edu.co/
dc.rights.localAcceso abiertospa
dc.rights.creativecommonsAttribution-NonCommercial-NoDerivatives 4.0 International*
dc.title.translatedImplementation of the BISS in the operating room Clínica Cardio Vidspa
dc.type.localTrabajo de grado de pregradospa
dc.type.coarhttp://purl.org/coar/resource_type/c_7a1fspa
dc.type.driverinfo:eu-repo/semantics/bachelorThesisspa
dc.publisher.grantorInstituto Tecnológico Metropolitanospa
dc.description.degreelevelpregradospa


Ficheros en el ítem

Thumbnail
Thumbnail

Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo del ítem