Mostrar el registro sencillo del ítem
Análisis de un motor eléctrico tipo jaula de ardilla modificado en su estator para la disminución de potencia reactiva como variable principal de consumo
dc.contributor.advisor | Gómez Arango, Santiago | |
dc.contributor.author | Ocampo Valderrama, Julián Esteban | |
dc.contributor.author | García Sierra, Janer | |
dc.coverage.spatial | Medellín - Antioquia - Colombia | spa |
dc.date.accessioned | 2021-08-04T17:25:12Z | |
dc.date.available | 2021-08-04T17:25:12Z | |
dc.date.issued | 2021 | |
dc.identifier.uri | http://hdl.handle.net/20.500.12622/4685 | |
dc.description.abstract | Este trabajo presenta un análisis del rendimiento eléctrico en un motor de inducción tipo jaula de ardilla, mediante el estudio de diversas variables energéticas (potencia reactiva, presión de succión y descarga, potencia activa consumida, caudal bombeado) registrando los datos con un analizador de redes FLUKE 435 y softwares avanzados en pruebas estáticas y dinámicas de motores como es el del equipo para analizar motores eléctricos MCEmax® de PdMA Corporation. El motor de inducción seleccionado hace parte de un grupo de 5 motores que lleva aproximadamente 30 años en funcionamiento, por tanto, se declara en obsolescencia tecnológica y debido a su alto consumo energético fue seleccionado para su transformación con tecnología desarrollada por la empresa Maxeff Motors. Finalmente, los resultados obtenidos evidencian que la conversión realizada en un motor de 700 HP que gira a 1800 RPM fue exitosa; a tal punto, que el ahorro energético superó lo proyectado, por tanto, los 4 motores restantes de la instalación de bombeo de agua se convertirán gradualmente. | spa |
dc.format.mimetype | application/pdf | |
dc.language.iso | spa | spa |
dc.rights.uri | http://creativecommons.org/licenses/by-nc-nd/4.0/ | * |
dc.subject | Eficiencia energética | spa |
dc.subject | Potencia reactiva | spa |
dc.subject | Motor de inducción | spa |
dc.subject | Cogeneración | spa |
dc.subject | Variador de velocidad | spa |
dc.subject | Banco de condensadores | spa |
dc.title | Análisis de un motor eléctrico tipo jaula de ardilla modificado en su estator para la disminución de potencia reactiva como variable principal de consumo | spa |
dc.publisher.faculty | Facultad de Ingenierías | spa |
dc.publisher.program | Especialización en Gestión de Sistemas Energéticos Industriales | spa |
dc.subject.keywords | Energy efficiency | spa |
dc.subject.keywords | Reactive power | spa |
dc.subject.keywords | Induction motor | spa |
dc.subject.keywords | Cogeneration | spa |
dc.subject.keywords | Inverter speed | spa |
dc.subject.keywords | Capacitor bank | spa |
dc.subject.lemb | Motores eléctricos | spa |
dc.subject.lemb | Rendimiento energético | spa |
dc.description.abstractenglish | This work presents an analysis of the electrical performance in an induction motor type squirrel cage, by studying various energy variables (reactive power, suction and discharge pressure, consumed active power, pumped flow) recording data with a FLUKE 435 network analyzer and advanced software in testing statics and dynamics of motors such as that of the equipment to analyze electric motors MCEmax® from PdMA Corporation. The selected induction motor is part of a group of 5 motors that carries approximately 30 years in operation, therefore, it is declared obsolete technology and due to its high energy consumption it was selected for its transformation with technology developed by the Maxeff Motors company. Finally, the results obtained show that the conversion carried out in a motor 700 HP turning at 1800 RPM was successful; to such an extent that energy savings exceeded As projected, therefore, the remaining 4 engines of the water pumping installation are will gradually convert. | spa |
dc.description.degreename | Especialista en Gestión de Sistemas Energéticos Industriales | spa |
dc.identifier.instname | instname:Instituto Tecnológico Metropolitano | spa |
dc.identifier.reponame | reponame:Repositorio Institucional Instituto Tecnológico Metropolitano | spa |
dc.identifier.repourl | repourl:https://repositorio.itm.edu.co/ | |
dc.rights.local | Acceso abierto | spa |
dc.rights.accessrights | info:eu-repo/semantics/openAccess | |
dc.rights.creativecommons | Attribution-NonCommercial-NoDerivatives 4.0 International | * |
dc.title.translated | Analysis of a squirrel cage type electric motor modified in its stator to decrease reactive power as the main consumption variable | spa |
dc.type.local | Trabajo de grado de especialización | spa |
dc.type.coar | http://purl.org/coar/resource_type/c_7a1f | spa |
dc.type.driver | info:eu-repo/semantics/bachelorThesis | spa |
dc.publisher.grantor | Instituto Tecnológico Metropolitano | spa |
dc.description.degreelevel | pregrado | spa |