Cliente: Centro Comercia CityPlaza Centro Comercial CityPlaza Cr 36 D Sur # 27A105 Envigado 320 62 20 mantenimiento@cityplazacc.com Proyecto elaborado por: Juan Toro - Fabian Calle. ITM 319 269 0872 // 301 289 3571 Fecha: 11/01/2019 Iluminación Centro Comercial CityPlaza piso 1 Calculo de iluminación para el Centro Comercial CityPlaza piso 1 Índice Iluminación Centro Comercial CityPlaza piso 1 Vistas................................................................................................................................................................................................................................ 3 Iluminación Centro Comercial CityPlaza piso 1 SYLVANIA - P27405 LED HIGHBAY HBL2 110W (1xP27405 LED HIGHBAY HBL2 110W).................................................................................. 4 Terreno 1 Edificación 1 Planta (nivel) 1 Piso 1 Centro comercail Cityplaza Plano de situación de luminarias.................................................................................................................................................................... 7 Datos de mantenimiento............................................................................................................................................................................... 10 Descripción................................................................................................................................................................................................... 11 Lista de luminarias........................................................................................................................................................................................ 12 Vistas............................................................................................................................................................................................................ 13 Resumen de resultados de superficies.........................................................................................................................................................15 Plano útil (Piso 1 Centro comercail Cityplaza) / Intensidad lumínica perpendicular (Adaptativamente).......................................................16 Objeto de resultado de superficies 2 (Suelo/techo) / Intensidad lumínica perpendicular (Adaptativamente)...............................................18 Objeto de resultado de superficies 2 (Suelo/techo) / Densidad lumínica..................................................................................................... 20 Iluminación Centro Comercial CityPlaza piso 1 11/01/2019 Iluminación Centro Comercial CityPlaza piso 1 / Índice Página 2 Iluminación Centro Comercial CityPlaza piso 1 Piso 1. Iluminación Centro Comercial CityPlaza piso 1 11/01/2019 Iluminación Centro Comercial CityPlaza piso 1 / Vistas Página 3 SYLVANIA P27405 LED HIGHBAY HBL2 110W 1xP27405 LED HIGHBAY HBL2 110W Dispone de una imagen de la luminaria en nuestro catálogo de luminarias. Grado de eficacia de funcionamiento: 100.01% Flujo luminoso de lámparas: 14301 lm Flujo luminoso de las luminarias: 14303 lm Potencia: 111.8 W Rendimiento lumínico: 127.9 lm/W Indicaciones colorimétricas 1x: CCT 3000 K, CRI 100 Emisión de luz 1 / CDL polar 200 300 400 cd/klm η = 100% C0 - C180 C90 - C270 0° 15° 30° 45° 60° 75° 90° 105°105° 90° 75° 60° 45° 30° 15° 0° Iluminación Centro Comercial CityPlaza piso 1 11/01/2019 Terreno 1 / Edificación 1 / Planta (nivel) 1 / SYLVANIA P27405 LED HIGHBAY HBL2 110W 1xP27405 LED HIGHBAY HBL2 110W / SYLVANIA - P27405 LED HIGHBAY HBL2 110W (1xP27405 LED HIGHBAY HBL2 110W) Página 4 Emisión de luz 1 / CDL lineal 80 160 240 320 400 cd/klm η = 100% C0 - C180 C90 - C270 90.0° 67.5° 45.0° 22.5° 0.0° 22.5° 45.0° 67.5° 90.0° No se puede crear un diagrama de cono porque la distribución luminosa es asimétrica. Iluminación Centro Comercial CityPlaza piso 1 11/01/2019 Terreno 1 / Edificación 1 / Planta (nivel) 1 / SYLVANIA P27405 LED HIGHBAY HBL2 110W 1xP27405 LED HIGHBAY HBL2 110W / SYLVANIA - P27405 LED HIGHBAY HBL2 110W (1xP27405 LED HIGHBAY HBL2 110W) Página 5 Emisión de luz 1 / Diagrama de densidad lumínica 8000 16000 20000 g = 65.0° g = 75.0° g = 85.0° cd/m² C0 C45 C90 C135C180C225 C270 C315 No se puede crear un diagrama UGR porque la distribución luminosa es asimétrica. Iluminación Centro Comercial CityPlaza piso 1 11/01/2019 Terreno 1 / Edificación 1 / Planta (nivel) 1 / SYLVANIA P27405 LED HIGHBAY HBL2 110W 1xP27405 LED HIGHBAY HBL2 110W / SYLVANIA - P27405 LED HIGHBAY HBL2 110W (1xP27405 LED HIGHBAY HBL2 110W) Página 6 Piso 1 Centro comercail Cityplaza SYLVANIA P27405 LED HIGHBAY HBL2 110W N° X [m] Y [m] Altura de montaje [m] Factor de degradación 1 15.804 11.406 4.320 0.56 2 21.450 10.200 4.320 0.56 3 27.248 10.344 4.320 0.56 4 32.149 10.336 4.320 0.56 5 35.554 11.656 4.320 0.56 6 21.458 14.289 4.320 0.56 7 27.256 14.433 4.320 0.56 8 32.157 14.425 4.320 0.56 9 36.451 14.417 4.320 0.56 10 19.283 18.539 4.320 0.56 11 23.577 18.531 4.320 0.56 12 27.871 18.522 4.320 0.56 13 32.165 18.514 4.320 0.56 14 36.459 18.506 4.320 0.56 15 83.183 22.343 4.320 0.56 16 83.191 26.432 4.320 0.56 17 83.199 30.521 4.320 0.56 18 19.315 34.895 4.320 0.56 19 23.609 34.886 4.320 0.56 20 27.903 34.878 4.320 0.56 21 32.196 34.870 4.320 0.56 22 36.490 34.861 4.320 0.56 23 83.207 34.610 4.320 0.56 24 88.017 34.762 4.320 0.56 25 92.311 34.754 4.320 0.56 26 21.554 38.906 4.320 0.56 27 29.252 38.959 4.320 0.56 28 36.498 38.950 4.320 0.56 29 88.465 40.820 4.320 0.56 30 93.554 37.156 4.320 0.56 Iluminación Centro Comercial CityPlaza piso 1 11/01/2019 Terreno 1 / Edificación 1 / Planta (nivel) 1 / Piso 1 Centro comercail Cityplaza / Plano de situación de luminarias Página 7 N° X [m] Y [m] Altura de montaje [m] Factor de degradación 31 88.473 44.909 4.320 0.56 32 85.428 37.176 4.320 0.56 33 89.877 37.275 4.320 0.56 34 91.489 30.500 4.320 0.56 35 89.744 28.100 4.320 0.56 36 88.798 25.846 4.320 0.56 37 88.798 22.064 4.320 0.56 38 94.836 6.200 4.320 0.56 39 94.836 10.333 4.320 0.56 40 42.250 34.714 4.320 0.56 41 48.441 34.714 4.320 0.56 42 54.631 34.714 4.320 0.56 43 60.821 34.714 4.320 0.56 44 67.012 34.714 4.320 0.56 45 73.202 34.714 4.320 0.56 46 79.393 34.714 4.320 0.56 47 42.250 37.704 4.320 0.56 48 79.393 37.704 4.320 0.56 49 73.202 37.704 4.320 0.56 50 54.631 37.704 4.320 0.56 51 48.441 37.704 4.320 0.56 52 42.269 13.994 4.320 0.56 53 48.435 13.994 4.320 0.56 54 54.601 13.994 4.320 0.56 55 60.767 13.994 4.320 0.56 56 66.933 13.994 4.320 0.56 57 73.099 13.994 4.320 0.56 58 79.264 13.994 4.320 0.56 59 42.269 16.983 4.320 0.56 60 48.435 16.983 4.320 0.56 61 54.601 16.983 4.320 0.56 62 60.767 16.983 4.320 0.56 63 66.933 16.983 4.320 0.56 64 92.237 10.333 4.320 0.56 65 92.237 6.200 4.320 0.56 66 67.012 37.704 4.320 0.56 67 60.821 37.704 4.320 0.56 68 79.264 16.983 4.320 0.56 69 73.099 16.983 4.320 0.56 70 16.643 14.708 4.320 0.56 71 16.152 19.125 4.320 0.56 72 16.643 23.541 4.320 0.56 73 16.643 27.958 4.320 0.56 74 16.643 32.374 4.320 0.56 75 15.150 35.756 4.320 0.56 76 11.888 14.708 4.320 0.56 77 11.888 19.125 4.320 0.56 Iluminación Centro Comercial CityPlaza piso 1 11/01/2019 Terreno 1 / Edificación 1 / Planta (nivel) 1 / Piso 1 Centro comercail Cityplaza / Plano de situación de luminarias Página 8 N° X [m] Y [m] Altura de montaje [m] Factor de degradación 78 11.888 23.541 4.320 0.56 79 11.888 27.958 4.320 0.56 80 11.888 32.374 4.320 0.56 81 7.133 14.708 4.320 0.56 82 7.133 19.125 4.320 0.56 83 6.002 32.374 4.320 0.56 84 2.378 14.708 4.320 0.56 85 2.378 19.125 4.320 0.56 86 15.494 39.315 4.320 0.56 87 17.804 41.156 4.320 0.56 88 33.866 41.316 4.320 0.56 89 24.732 41.316 4.320 0.56 90 35.293 30.782 4.320 0.56 91 35.293 26.345 4.320 0.56 92 35.293 21.909 4.320 0.56 93 38.434 30.782 4.320 0.56 94 38.434 21.909 4.320 0.56 95 38.434 26.345 4.320 0.56 96 82.854 13.907 4.320 0.56 97 87.623 13.903 4.320 0.56 98 92.392 13.900 4.320 0.56 99 97.161 13.896 4.320 0.56 100 82.857 16.947 4.320 0.56 101 87.625 16.943 4.320 0.56 102 22.173 3.799 4.320 0.56 103 28.440 3.799 4.320 0.56 104 22.174 7.599 4.320 0.56 105 28.440 7.599 4.320 0.56 106 2.289 34.766 4.320 0.56 107 8.999 34.766 4.320 0.56 108 2.289 37.607 4.320 0.56 109 6.868 37.607 4.320 0.56 110 11.447 37.607 4.320 0.56 111 1.822 27.543 4.320 0.56 112 1.822 22.497 4.320 0.56 113 5.465 27.543 4.320 0.56 114 5.465 22.497 4.320 0.56 115 4.839 30.460 4.320 0.56 116 92.394 16.940 4.320 0.56 117 97.163 16.936 4.320 0.56 118 25.252 5.637 4.320 0.56 Iluminación Centro Comercial CityPlaza piso 1 11/01/2019 Terreno 1 / Edificación 1 / Planta (nivel) 1 / Piso 1 Centro comercail Cityplaza / Plano de situación de luminarias Página 9 Piso 1 Centro comercail Cityplaza Informaciones generales sobre el local Método de factor de mantenimiento CIE 97:2005 Condición ambiental Normal Intervalo de limpieza 1.0 Años Luminaria Datos de mantenimiento 118 Pieza SYLVANIA - P27405 LED HIGHBAY HBL2 110W Lámpara: 1 Pieza 1xP27405 LED HIGHBAY HBL2 110W 111.8 W Intervalo de limpieza 2.0 Años Tipo de iluminación Directo Tipo de luminarias Cerrado IP2X Horas de trabajo anuales 5500 h Tipo de lámpara Lámpara de vapor de sodio a presión baja Intervalo de cambio de lámparas 4.0 Años Cambiar lámparas defectuosas inmediatamente Sí Factor de mantenimiento del espacio (RMF) 0.92 Factor de mantenimiento de las luminarias (LMF) 0.77 Factor de mantenimiento del flujo luminoso (LLMF) 0.79 Factor de vida útil de la lámpara (LSF) 1.00 Factor de degradación (MF) 0.56 Iluminación Centro Comercial CityPlaza piso 1 11/01/2019 Terreno 1 / Edificación 1 / Planta (nivel) 1 / Piso 1 Centro comercail Cityplaza / Datos de mantenimiento Página 10 Piso 1 Centro comercail Cityplaza Nota: Este cálculo no comprende zanas de servicios sanitarios ni escalas, debido a que su consumo no es significativo. Iluminación Centro Comercial CityPlaza piso 1 11/01/2019 Terreno 1 / Edificación 1 / Planta (nivel) 1 / Piso 1 Centro comercail Cityplaza / Descripción Página 11 Piso 1 Centro comercail Cityplaza Número de unidades Luminaria (Emisión de luz) 118 SYLVANIA - P27405 LED HIGHBAY HBL2 110W Emisión de luz 1 Lámpara: 1xP27405 LED HIGHBAY HBL2 110W Grado de eficacia de funcionamiento: 100.01% Flujo luminoso de lámparas: 14301 lm Flujo luminoso de las luminarias: 14303 lm Potencia: 111.8 W Rendimiento lumínico: 127.9 lm/W Indicaciones colorimétricas 1x: CCT 3000 K, CRI 100 Dispone de una imagen de la luminaria en nuestro catálogo de luminarias. Flujo luminoso total de lámparas: 1687518 lm, Flujo luminoso total de luminarias: 1687754 lm, Potencia total: 13192.4 W, Rendimiento lumínico: 127.9 lm/W Iluminación Centro Comercial CityPlaza piso 1 11/01/2019 Terreno 1 / Edificación 1 / Planta (nivel) 1 / Piso 1 Centro comercail Cityplaza / Lista de luminarias Página 12 Piso 1 Centro comercail Cityplaza Piso 1 Resultados 2D Escala: 1 : 750 Iluminación Centro Comercial CityPlaza piso 1 11/01/2019 Terreno 1 / Edificación 1 / Planta (nivel) 1 / Piso 1 Centro comercail Cityplaza / Vistas Página 13 Piso 1 resultados 3D Iluminación Centro Comercial CityPlaza piso 1 11/01/2019 Terreno 1 / Edificación 1 / Planta (nivel) 1 / Piso 1 Centro comercail Cityplaza / Vistas Página 14 Piso 1 Centro comercail Cityplaza Altura interior del local: 0.000 m hasta 4.320 m, Grado de reflexión: Techo 68.6%, Paredes 70.6%, Suelo 75.2%, Factor de degradación: Véase la hoja de datos de mantenimiento General Superficie Resultado Media (Nominal) Min Max Mín./medio Mín./máx. 1 Superficie de cálculo 2 Intensidad lumínica perpendicular [lx] Altura: 0.000 m 613 1.33 773 0.002 0.002 Objetos de resultado de superficies 2 Objeto de resultado de superficies 2 (Suelo/techo) Intensidad lumínica perpendicular (Adaptativamente) [lx] 601 0.90 838 0.001 0.001 Densidad lumínica [cd/m²] 142 0.21 198 0.001 0.001 Iluminación Centro Comercial CityPlaza piso 1 11/01/2019 Terreno 1 / Edificación 1 / Planta (nivel) 1 / Piso 1 Centro comercail Cityplaza / Resumen de resultados de superficies Página 15 Plano útil (Piso 1 Centro comercail Cityplaza) / Intensidad lumínica perpendicular (Adaptativamente) Plano útil (Piso 1 Centro comercail Cityplaza): Intensidad lumínica perpendicular (Adaptativamente) (Superficie) Escena de luz: Escena de luz 1 Media: 616 lx (Nominal: ≥ 500 lx), Min: 0.90 lx, Max: 842 lx, Mín./medio: 0.001, Mín./máx.: 0.001 Altura: 0.000 m, Zona marginal: 0.000 m Isolíneas [lx] Escala: 1 : 750 Iluminación Centro Comercial CityPlaza piso 1 11/01/2019 Terreno 1 / Edificación 1 / Planta (nivel) 1 / Piso 1 Centro comercail Cityplaza / Plano útil (Piso 1 Centro comercail Cityplaza) / Intensidad lumínica perpendicular (Adaptativamente) Página 16 Colores falsos [lx] Escala: 1 : 750 Sistema de valores [lx] Escala: 1 : 750 Iluminación Centro Comercial CityPlaza piso 1 11/01/2019 Terreno 1 / Edificación 1 / Planta (nivel) 1 / Piso 1 Centro comercail Cityplaza / Plano útil (Piso 1 Centro comercail Cityplaza) / Intensidad lumínica perpendicular (Adaptativamente) Página 17 Objeto de resultado de superficies 2 (Suelo/techo) / Intensidad lumínica perpendicular (Adaptativamente) Objeto de resultado de superficies 2 (Suelo/techo): Intensidad lumínica perpendicular (Adaptativamente) (Superficie) Escena de luz: Escena de luz 1 Media: 601 lx, Min: 0.90 lx, Max: 838 lx, Mín./medio: 0.001, Mín./máx.: 0.001 Isolíneas [lx] Escala: 1 : 750 Iluminación Centro Comercial CityPlaza piso 1 11/01/2019 Terreno 1 / Edificación 1 / Planta (nivel) 1 / Piso 1 Centro comercail Cityplaza / Objeto de resultado de superficies 2 (Suelo/techo) / Intensidad lumínica perpendicular (Adaptativamente) Página 18 Colores falsos [lx] Escala: 1 : 750 Sistema de valores [lx] Escala: 1 : 750 Iluminación Centro Comercial CityPlaza piso 1 11/01/2019 Terreno 1 / Edificación 1 / Planta (nivel) 1 / Piso 1 Centro comercail Cityplaza / Objeto de resultado de superficies 2 (Suelo/techo) / Intensidad lumínica perpendicular (Adaptativamente) Página 19 Objeto de resultado de superficies 2 (Suelo/techo) / Densidad lumínica Objeto de resultado de superficies 2 (Suelo/techo): Densidad lumínica (Superficie) Escena de luz: Escena de luz 1 Media: 142 cd/m², Min: 0.21 cd/m², Max: 198 cd/m², Mín./medio: 0.001, Mín./máx.: 0.001 Isolíneas [cd/m²] Escala: 1 : 750 Iluminación Centro Comercial CityPlaza piso 1 11/01/2019 Terreno 1 / Edificación 1 / Planta (nivel) 1 / Piso 1 Centro comercail Cityplaza / Objeto de resultado de superficies 2 (Suelo/techo) / Densidad lumínica Página 20 Colores falsos [cd/m²] Escala: 1 : 750 Sistema de valores [cd/m²] Escala: 1 : 750 Iluminación Centro Comercial CityPlaza piso 1 11/01/2019 Terreno 1 / Edificación 1 / Planta (nivel) 1 / Piso 1 Centro comercail Cityplaza / Objeto de resultado de superficies 2 (Suelo/techo) / Densidad lumínica Página 21